Short Circuit Loop Impedance Meter Sonel MZC-304F
SKU: SL-MZC-304F-EU-R1
Free shipping over 200 EUR
Estimated shipping time 3-4 weeks
Estimated shipping time 3-4 weeks
Product information | |
---|---|
Product name | Short Circuit Loop Impedance Meter Sonel MZC-304F |
Brand | Sonel |
Voltage | |
Measurement range | 0 V - 500 V |
Display range | 0 V - 500 V |
Resolution | from 0.1 V |
Accuracy ±(% m.v. + digits) | from ±(2 % m.v. + 2 digits) |
Short-circuit loop parameters: 2p method - standard current measurement | |
Maximum current | 13.3 A |
Measurement range | from 0.13 Ω - 1999 Ω |
Display range | 0.00 Ω - 1999 Ω |
Resolution | from 0.01 Ω |
Accuracy ±(% m.v. + digits) | ±(5% m.v. + 3 digits) |
Short-circuit loop parameters: 2p method - measurements without tripping RCDs | |
Measurement range | from 0.5 Ω…1999 Ω |
Display range | 0.00 Ω - 1999 Ω |
Resolution | from 0.01 Ω |
Accuracy ±(% m.v. + digits) | from ±(6 % m.v. + 5 digits) |
Short-circuit current readings: 2p method - standard current measurement | |
Measurement range | Calculated on the basis of test ZS ranges and rated voltages |
Display range | 1.110 A…9999 A |
Resolution | from 0.001 A |
Accuracy ±(% m.v. + digits) | Calculated on the basis of error for fault loop |
Short-circuit current readings: 2p method - measurements without tripping RCDs | |
Measurement range | Calculated on the basis of test ZS ranges and rated voltages |
Display range | 1.110 A…9999 A |
Resolution | from 0.001 A |
Accuracy ±(% m.v. + digits) | Calculated on the basis of error for fault loop |
Low-voltage measurement of continuity of circuit and resistance with ±200 mA current | |
Measurement range | 0.12 Ω…400 Ω |
Display range | 0.00 Ω…400 Ω |
Resolution | from 0.01 Ω |
Accuracy ±(% m.v. + digits) | ±(2% m.v. + 3 digits) |
Measurement of resistance with low current | |
Measurement range | 0.0 Ω…1999 Ω |
Display range | 0.0 Ω…1999 Ω |
Resolution | from 0.1 Ω |
Accuracy ±(% m.v. + digits) | ±(3% m.v. + 3 digits) |
Environmental Conditions | |
Measuring category acc. to EN 61010 | IV 300 V, III 600 V |
Ingress protection | IP54 |
Type of insulation according to EN 61010-1 and EN 61557 | double |
Operating temperature | 0 - +50 °C |
Storage temperature | -20 - +70 °C |
Humidity | 20 - 90 % |
Nominal temperature | 23 ± 2 °C |
Reference humidity | 40 % - 60 % |
Power supply | 4x LR6 1.5 V alkaline battery, 4x AA size NiMH rechargeable battery |
Applicable Standards | |
Quality standard – development, design and production | ISO 9001 |
EMC (emission for industrial environment) | EN 61326-1, EN 61326-2-2 |
Data Storage | |
Internal memory | Memory of measurement results - 990 results |
Computer Interface | |
Data transmission | Bluetooth |
Dimensions and Weight | |
Dimensions (W x H x D) | 102 x 220 x 61 mm (4,0 x 8,7 x 2,4 in) |
Weight | 0.8 kg (1,8 lbs) |
- WS-05 Adapter with UNI-SCHUKO angular plug
- Alkaline battery AA LR06 (15A) 1.5 V (4pcs)
- Factory calibration certificate
- M-6 Carrying case
- K-02 Crocodile clip, yellow, 1 kV, 20 A
- M-1 Hanging straps
- Hanging hook straps
- Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) blue
- Test lead 1.2 m, 1 kV (banana plugs) red
- Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) yellow
- Pin probe, blue 1 kV (banana socket)
- Pin probe CAT III/1000V CAT IV/600V (banana socket) red
- Short Circuit Loop Impedance Meter MZC-304F