Multifunctional Electrical Installations Meter Sonel MPI-536

SKU: SL-MPI-536-EU-R1

Multifunctional meter referred to as “insulation resistance specialist”:

  • Measurement of insulation resistance using test voltage up to 2,5 kV
  • 7 ‘’ touch screen enabling visualization of results
  • Measurement of all earthing and electric shock-related parameters with a single device
Free shipping over 200 EUR
Estimated shipping time 3-4 weeks

The Sonel MPI-536 meter is designed to help you inspect electrical installations in commercial and residential buildings quickly and efficiently. Data provided with this multifunctional meter can help you identify how safe installation is.

The standout feature of multifunction meter MPI-536: high test voltage of up to 2,5 kV

One of the standout features of the Sonel MPI series is its ability to measure insulation resistance accurately. With a test voltage of 2,5 kV, the MPI-536 can measure insulation resistance up to 10 GΩ, making it perfect for use in high-voltage applications. The size of the display (7 '') is large enough to enable a clear, easy-to-read, result view. Plotting graphs make it easy to visualize and analyze data. The plotting feature is available both, during and after, measurement and it supports graphs: R(t)/U(t), R(t)/I (t), U(t)/I(t), I(U). The multifunction meter can be operated with dielectric gloves due to included stylus.

Electrical installations meter built to last: IP51

The MPI-536 is built to last, with increased resistance to environmental conditions. This makes it a reliable tool that can withstand harsh conditions and rough handling. The four measurement methods for earth resistance, including soil resistivity measurement, make it easy to get accurate readings even in challenging environments.

Measurement automation

Residential, commercial, and industrial electrical infrastructure can be safely controlled thanks to MPI-536. Measurement automation is simple with:
  • Auto mode of residual current devices (RCD) tests
  • Auto measurements – freely configurable measuring sequences
  • AutoISO-1000C adapter for automatic insulation resistance test of 3-, 4- and 5-conductor cables, without switching
  • Features

    MPI-536 insulation resistance specialist features:
  • Measurement of insulation resistance using a test voltage of 2.5 kV
  • Visualization of RISO in the form of a graph
  • The largest touch screen on the market (7”) – remarkable ergonomics and ease of use
  • Removable microSD memory card – an easy increase of memory capacity
  • Li-Ion battery – longer operation of the meter
  • Measurement of all parameters related to earthing and protection against electric shock – one device instead of several
  • Quick measurement of the fault loop impedance in networks secured with RCD without triggering (up to several seconds) – time saver
  • Auto measurements – the ability to perform automatic measurements in sequence – simplified measurements
  • Fast path from measurements to report – time saver
  • The Sonel MPI-536 is a multifunctional meter that can be used for a wide range of applications, including:

  • Short circuit loop impedance (also in circuits secured with RCDs)
  • RCD parameters
  • Insulation resistance
  • Earth resistance (4 measurement methods + soil resistivity measurement)
  • Continuity of protective and equipotential bondings
  • Light intensity measurement
  • Phase sequence test
  • Motor rotation direction test
  • With its versatility and professional-grade features, the Sonel Multifunctional Electrical Installations Meter MPI-536 is an indispensable tool for any electrical testing needs. Place your order now and experience the exceptional power of this incredible multimeter.

    Product information
    Product name Multifunctional Electrical Installations Meter Sonel MPI-536
    Brand Sonel
    Fault loop impedance ZL-PE, ZL-N, ZL-L
    Measurement range 0,13 - 1999 Ω
    Display range 0 - 1999 Ω
    Resolution from 0,001 Ω
    Accuracy ±(%m.v. + digits) ±(5 % m.v. + 30 digits)
    Fault loop impedance ZL-PE in RCD mode
    Measurement range from 0,50 - 1999 Ω
    Display range 0 - 1999 Ω
    Resolution from 0,01 Ω
    Accuracy ±(%m.v. + digits) ±(6 % m.v. + 5 digits)
    General and short-time delay RCD
    Measurement range 0 - 300 ms
    Display range 0 - 300 ms
    Resolution 1 ms
    Accuracy ±(%m.v. + digits) ±(2 % m.v. + 2 digits)
    Selective RCD
    Measurement range 0 - 500 ms
    Display range 0 - 500 ms
    Resolution 1 ms
    Accuracy ±(%m.v. + digits) ±(2 % m.v. + 2 digits)
    For sinusoidal residual current (AC type)
    Measurement range 3,3 mA - 1000 mA
    Display range 3,3 mA - 1000 mA
    Resolution from 0,1 mA
    Accuracy ±(%m.v. + digits) ±5 % IΔn
    For unidirectional residual current and unidirectional with the 6 mA DC bias (type A)
    Measurement range 3,5 mA - 700 mA
    Display range 3,5 mA - 700 mA
    Resolution from 0,1 mA
    Accuracy ±(%m.v. + digits) ±10 % IΔn
    For direct residual current (type B)
    Measurement range 2,0 mA - 1000 mA
    Display range 2,0 mA - 1000 mA
    Resolution from 0,1 mA
    Accuracy ±(%m.v. + digits) ±10 % IΔn
    Earth resistance - 3-pole method
    Measurement range from 0,50 Ω - 1,99 kΩ
    Display range 0 - 1,99 kΩ
    Resolution from 0,01 Ω
    Accuracy ±(%m.v. + digits) from ±(2 % m.v. + 3 digits)
    Earth resistance - 4-pole method
    Measurement range from 0,50 Ω - 1,99 kΩ
    Display range 0 - 1,99 kΩ
    Resolution from 0,01 Ω
    Accuracy ±(%m.v. + digits) from ±(2 % m.v. + 3 digits)
    Earth resistance - 3-pole + clamp method
    Measurement range 0,00 Ω - 1,99 kΩ
    Display range 0,00 Ω - 1,99 kΩ
    Resolution from 0,01 Ω
    Accuracy ±(%m.v. + digits) ±(2 % m.v. + 4 digits)
    Earth resistance - 2-clamp method
    Measurement range 0,00 Ω - 99,9 kΩ
    Display range 0,00 Ω - 99,9 kΩ
    Resolution from 0,01 Ω
    Accuracy ±(%m.v. + digits) from ±(10 % m.v. + 4 digits)
    Resistance-to-earth
    Measurement range 0,00 Ωm - 99,9 kΩm
    Display range 0,00 Ωm - 99,9 kΩm
    Resolution from 0,1 Ωm
    Accuracy ±(%m.v. + digits) Depending on accuracy
    of RE measurement
    Insulation resistance - Measuring voltage 10 V
    Measurement range 10 kΩ - 9,99 MΩ
    Display range 0 kΩ - 9,99 MΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
    Insulation resistance - Measuring voltage 50 V
    Measurement range 50 kΩ - 250 MΩ
    Display range 0 kΩ - 250 MΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
    Insulation resistance - Measuring voltage 100 V
    Measurement range 100 kΩ - 500 MΩ
    Display range 0 kΩ - 500 MΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
    Insulation resistance - Measuring voltage 250 V
    Measurement range 250 kΩ - 999 MΩ
    Display range 0 kΩ - 999 MΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
    Insulation resistance - Measuring voltage 500 V
    Measurement range 500 kΩ - 2 GΩ
    Display range 0 kΩ - 2 GΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3% m.v. + 8 digits)
    Insulation resistance - Measuring voltage 1000 V
    Measurement range 1000 kΩ - 3 GΩ
    Display range 0 kΩ - 3 GΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
    Insulation resistance - Measuring voltage 1500 V
    Measurement range 1500 kΩ - 5 GΩ
    Display range 0 kΩ - 5 GΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
    Insulation resistance - Measuring voltage 2500 V
    Measurement range 2500 kΩ - 9,99 GΩ
    Display range 0 kΩ - 9,99 GΩ
    Resolution from 1 kΩ
    Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
    Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current
    Measurement range 0,12 Ω - 400 Ω
    Display range 0 - 400 Ω
    Resolution from 0,01 Ω
    Accuracy ±(%m.v. + digits) ±(2 % m.v. + 3 digits)
    Measurement of resistance with low current
    Measurement range 0 Ω - 1999 Ω
    Display range 0 - 1999 Ω
    Resolution from 0,1 Ω
    Accuracy ±(%m.v. + digits) ±(3 % m.v. + 3 digits)
    Measurement in luxes (lx)
    Measurement range 0 lx - 399,9 klx
    Display range 0 lx - 399,9 klx
    Resolution from 0,001 lx
    Accuracy ±(%m.v. + digits) from ±(2% m.v. + 5 digits)
    Measurement in feet-candles (fc)
    Measurement range 0 fc - 39,99 kfc
    Display range 0 fc - 39,99 kfc
    Resolution from 0,001 fc
    Accuracy ±(%m.v. + digits) from ±(2 % m.v. + 5 digits)
    Environmental Conditions
    Ingress protection IP51
    Operating temperature 0 - 45 °C
    Storage temperature -20 - 60 °C
    Humidity 20 - 90 %
    Nominal temperature 23 ± 2 °C
    Reference humidity 40 - 60 %
    Measuring category acc. to EN 61010 IV 300 V, III 500 V
    Type of insulation acc. to EN 61010-1 and IEC 61557 double
    Data Storage
    Memory unlimited
    Computer Interface
    Data transmission USB 2.0
    Dimensions and Weight
    Dimensions (W x H x D) 223 x 288 x 75 mm (8,8 x 11,3 x 3,0 in)
    Weight 2.5 kg (5,5 lbs)
    • WS-03 Adapter with START button with UNI-SCHUKO plug
    • AKU-15 Li-ion battery 11.1 V 3.4 Ah
    • Factory calibration certificate
    • L-2 Carrying case
    • K-09 Crocodile clip, black, 11 kV, 32 A
    • K-02 Crocodile clip, blue, 1 kV, 20 A
    • K-02 Crocodile clip, red, 1 kV, 20 A
    • K-02 Crocodile clip, yellow, 1 kV, 20 A
    • Hanging straps
    • Touchscreen pen
    • Sonel pendrive
    • Sonel Reader
    • Test lead 15 m for earth resistance measurements (on a reel, banana plugs) blue
    • Test lead 30 m for earth resistance measurements (on a reel, banana plugs) red
    • Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) blue
    • Test lead 1.2 m, 1 kV (banana plugs) red
    • Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) yellow
    • Test lead 1.8 m 5 kV (banana plugs, shielded) black/graphite
    • Test lead 1.8 m 5 kV (banana plugs) red
    • Cable for battery charging from car cigarette lighter socket (12 V)
    • Mains power cable 230 V (IEC C7 plug)
    • USB cable
    • Pin probe, blue 1 kV (banana socket)
    • Earth contact test probe (rod), 30 cm (2pcs)
    • Pin probe CAT III/1000V CAT IV/600V (banana socket) red
    • Pin probe 5 kV (banana socket) red
    • Pin probe CAT III/1000V CAT IV/600V (banana socket) yellow
    • Z-7 Power supply adapter
    • MPI-536 meter

    MPI-536 features wide range of communication interfaces and can work with third-party software. Obtained data from device can be transferred to a computer in several ways: using USB port, removable SD memory card, or wireless communication (Bluetooth*, Wi-Fi ).
    Use Sonel Reports PLUS software to create a report measurement for electric shock protection. Free Sonel Reader software enables printing and saving of downloaded data to the majority of simple file formats.