Multifunctional Electrical Installations Meter Sonel MPI-536
SKU: SL-MPI-536-EU-R1
Multifunctional meter referred to as “insulation resistance specialist”:
- Measurement of insulation resistance using test voltage up to 2,5 kV
- 7 ‘’ touch screen enabling visualization of results
- Measurement of all earthing and electric shock-related parameters with a single device
Estimated shipping time 3-4 weeks
The Sonel MPI-536 meter is designed to help you inspect electrical installations in commercial and residential buildings quickly and efficiently. Data provided with this multifunctional meter can help you identify how safe installation is.
The standout feature of multifunction meter MPI-536: high test voltage of up to 2,5 kV
One of the standout features of the Sonel MPI series is its ability to measure insulation resistance accurately. With a test voltage of 2,5 kV, the MPI-536 can measure insulation resistance up to 10 GΩ, making it perfect for use in high-voltage applications. The size of the display (7 '') is large enough to enable a clear, easy-to-read, result view. Plotting graphs make it easy to visualize and analyze data. The plotting feature is available both, during and after, measurement and it supports graphs: R(t)/U(t), R(t)/I (t), U(t)/I(t), I(U). The multifunction meter can be operated with dielectric gloves due to included stylus.Electrical installations meter built to last: IP51
The MPI-536 is built to last, with increased resistance to environmental conditions. This makes it a reliable tool that can withstand harsh conditions and rough handling. The four measurement methods for earth resistance, including soil resistivity measurement, make it easy to get accurate readings even in challenging environments.Measurement automation
Residential, commercial, and industrial electrical infrastructure can be safely controlled thanks to MPI-536. Measurement automation is simple with:Features
MPI-536 insulation resistance specialist features:The Sonel MPI-536 is a multifunctional meter that can be used for a wide range of applications, including:
Product information | |
---|---|
Product name | Multifunctional Electrical Installations Meter Sonel MPI-536 |
Brand | Sonel |
Fault loop impedance ZL-PE, ZL-N, ZL-L | |
Measurement range | 0,13 - 1999 Ω |
Display range | 0 - 1999 Ω |
Resolution | from 0,001 Ω |
Accuracy ±(%m.v. + digits) | ±(5 % m.v. + 30 digits) |
Fault loop impedance ZL-PE in RCD mode | |
Measurement range | from 0,50 - 1999 Ω |
Display range | 0 - 1999 Ω |
Resolution | from 0,01 Ω |
Accuracy ±(%m.v. + digits) | ±(6 % m.v. + 5 digits) |
General and short-time delay RCD | |
Measurement range | 0 - 300 ms |
Display range | 0 - 300 ms |
Resolution | 1 ms |
Accuracy ±(%m.v. + digits) | ±(2 % m.v. + 2 digits) |
Selective RCD | |
Measurement range | 0 - 500 ms |
Display range | 0 - 500 ms |
Resolution | 1 ms |
Accuracy ±(%m.v. + digits) | ±(2 % m.v. + 2 digits) |
For sinusoidal residual current (AC type) | |
Measurement range | 3,3 mA - 1000 mA |
Display range | 3,3 mA - 1000 mA |
Resolution | from 0,1 mA |
Accuracy ±(%m.v. + digits) | ±5 % IΔn |
For unidirectional residual current and unidirectional with the 6 mA DC bias (type A) | |
Measurement range | 3,5 mA - 700 mA |
Display range | 3,5 mA - 700 mA |
Resolution | from 0,1 mA |
Accuracy ±(%m.v. + digits) | ±10 % IΔn |
For direct residual current (type B) | |
Measurement range | 2,0 mA - 1000 mA |
Display range | 2,0 mA - 1000 mA |
Resolution | from 0,1 mA |
Accuracy ±(%m.v. + digits) | ±10 % IΔn |
Earth resistance - 3-pole method | |
Measurement range | from 0,50 Ω - 1,99 kΩ |
Display range | 0 - 1,99 kΩ |
Resolution | from 0,01 Ω |
Accuracy ±(%m.v. + digits) | from ±(2 % m.v. + 3 digits) |
Earth resistance - 4-pole method | |
Measurement range | from 0,50 Ω - 1,99 kΩ |
Display range | 0 - 1,99 kΩ |
Resolution | from 0,01 Ω |
Accuracy ±(%m.v. + digits) | from ±(2 % m.v. + 3 digits) |
Earth resistance - 3-pole + clamp method | |
Measurement range | 0,00 Ω - 1,99 kΩ |
Display range | 0,00 Ω - 1,99 kΩ |
Resolution | from 0,01 Ω |
Accuracy ±(%m.v. + digits) | ±(2 % m.v. + 4 digits) |
Earth resistance - 2-clamp method | |
Measurement range | 0,00 Ω - 99,9 kΩ |
Display range | 0,00 Ω - 99,9 kΩ |
Resolution | from 0,01 Ω |
Accuracy ±(%m.v. + digits) | from ±(10 % m.v. + 4 digits) |
Resistance-to-earth | |
Measurement range | 0,00 Ωm - 99,9 kΩm |
Display range | 0,00 Ωm - 99,9 kΩm |
Resolution | from 0,1 Ωm |
Accuracy ±(%m.v. + digits) | Depending on accuracy |
of RE measurement | |
Insulation resistance - Measuring voltage 10 V | |
Measurement range | 10 kΩ - 9,99 MΩ |
Display range | 0 kΩ - 9,99 MΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3 % m.v. + 8 digits) |
Insulation resistance - Measuring voltage 50 V | |
Measurement range | 50 kΩ - 250 MΩ |
Display range | 0 kΩ - 250 MΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3 % m.v. + 8 digits) |
Insulation resistance - Measuring voltage 100 V | |
Measurement range | 100 kΩ - 500 MΩ |
Display range | 0 kΩ - 500 MΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3 % m.v. + 8 digits) |
Insulation resistance - Measuring voltage 250 V | |
Measurement range | 250 kΩ - 999 MΩ |
Display range | 0 kΩ - 999 MΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3 % m.v. + 8 digits) |
Insulation resistance - Measuring voltage 500 V | |
Measurement range | 500 kΩ - 2 GΩ |
Display range | 0 kΩ - 2 GΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3% m.v. + 8 digits) |
Insulation resistance - Measuring voltage 1000 V | |
Measurement range | 1000 kΩ - 3 GΩ |
Display range | 0 kΩ - 3 GΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3 % m.v. + 8 digits) |
Insulation resistance - Measuring voltage 1500 V | |
Measurement range | 1500 kΩ - 5 GΩ |
Display range | 0 kΩ - 5 GΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3 % m.v. + 8 digits) |
Insulation resistance - Measuring voltage 2500 V | |
Measurement range | 2500 kΩ - 9,99 GΩ |
Display range | 0 kΩ - 9,99 GΩ |
Resolution | from 1 kΩ |
Accuracy ±(%m.v. + digits) | from ±(3 % m.v. + 8 digits) |
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | |
Measurement range | 0,12 Ω - 400 Ω |
Display range | 0 - 400 Ω |
Resolution | from 0,01 Ω |
Accuracy ±(%m.v. + digits) | ±(2 % m.v. + 3 digits) |
Measurement of resistance with low current | |
Measurement range | 0 Ω - 1999 Ω |
Display range | 0 - 1999 Ω |
Resolution | from 0,1 Ω |
Accuracy ±(%m.v. + digits) | ±(3 % m.v. + 3 digits) |
Measurement in luxes (lx) | |
Measurement range | 0 lx - 399,9 klx |
Display range | 0 lx - 399,9 klx |
Resolution | from 0,001 lx |
Accuracy ±(%m.v. + digits) | from ±(2% m.v. + 5 digits) |
Measurement in feet-candles (fc) | |
Measurement range | 0 fc - 39,99 kfc |
Display range | 0 fc - 39,99 kfc |
Resolution | from 0,001 fc |
Accuracy ±(%m.v. + digits) | from ±(2 % m.v. + 5 digits) |
Environmental Conditions | |
Ingress protection | IP51 |
Operating temperature | 0 - 45 °C |
Storage temperature | -20 - 60 °C |
Humidity | 20 - 90 % |
Nominal temperature | 23 ± 2 °C |
Reference humidity | 40 - 60 % |
Measuring category acc. to EN 61010 | IV 300 V, III 500 V |
Type of insulation acc. to EN 61010-1 and IEC 61557 | double |
Data Storage | |
Memory | unlimited |
Computer Interface | |
Data transmission | USB 2.0 |
Dimensions and Weight | |
Dimensions (W x H x D) | 223 x 288 x 75 mm (8,8 x 11,3 x 3,0 in) |
Weight | 2.5 kg (5,5 lbs) |
- WS-03 Adapter with START button with UNI-SCHUKO plug
- AKU-15 Li-ion battery 11.1 V 3.4 Ah
- Factory calibration certificate
- L-2 Carrying case
- K-09 Crocodile clip, black, 11 kV, 32 A
- K-02 Crocodile clip, blue, 1 kV, 20 A
- K-02 Crocodile clip, red, 1 kV, 20 A
- K-02 Crocodile clip, yellow, 1 kV, 20 A
- Hanging straps
- Touchscreen pen
- Sonel pendrive
- Sonel Reader
- Test lead 15 m for earth resistance measurements (on a reel, banana plugs) blue
- Test lead 30 m for earth resistance measurements (on a reel, banana plugs) red
- Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) blue
- Test lead 1.2 m, 1 kV (banana plugs) red
- Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) yellow
- Test lead 1.8 m 5 kV (banana plugs, shielded) black/graphite
- Test lead 1.8 m 5 kV (banana plugs) red
- Cable for battery charging from car cigarette lighter socket (12 V)
- Mains power cable 230 V (IEC C7 plug)
- USB cable
- Pin probe, blue 1 kV (banana socket)
- Earth contact test probe (rod), 30 cm (2pcs)
- Pin probe CAT III/1000V CAT IV/600V (banana socket) red
- Pin probe 5 kV (banana socket) red
- Pin probe CAT III/1000V CAT IV/600V (banana socket) yellow
- Z-7 Power supply adapter
- MPI-536 meter
MPI-536 features wide range of communication interfaces and can work with third-party software. Obtained data from device can be transferred to a computer in several ways: using USB port, removable SD memory card, or wireless communication (Bluetooth*, Wi-Fi ).
Use Sonel Reports PLUS software to create a report measurement for electric shock protection. Free Sonel Reader software enables printing and saving of downloaded data to the majority of simple file formats.