Multifunctional Electrical Installations Meter Sonel MPI-530

SKU: SL-MPI-530-EU-R1

Multifunction meter for commissioning of electrical installations and power quality analysis (1-phase).

  • Electrical installations (short circuit loop parameters, insulation resistance, etc.)
  • Extensive ground measurement functions
  • Enables illumination intensity testing
Kostenloser Versand über 200 EUR
Geschätzte Versandzeit 3-4 weeks
Why Choose Sonel MPI-530 Multifunctional Electrical Installations Meter? Have you ever found yourself struggling with multiple tools for electrical installations, safety inspections, and power quality checks? The Sonel MPI-530 Multifunctional Electrical Installations Meter is the perfect solution for all your electrical needs.Designed to be professional and versatile, the Sonel MPI-530 Multimeter is a robust and reliable instrument that can withstand tough environmental conditions. Whether you're a professional electrician or a DIY enthusiast, this multimeter is the ultimate tool that delivers accurate readings with ease.The Sonel MPI-530 Multimeter is equipped with a range of features that make the commissioning of electrical installations, an inspection of electrical safety, and power quality checks a breeze. With a clear and easy-to-read display, you can easily monitor voltage, current, frequency, power, and other critical parameters in real time. Improved ability to withstand environmental conditions The multimeter's increased resistance to environmental conditions makes it the perfect tool for use in harsh environments. The device is built with a rugged and durable design that can withstand the toughest conditions while still providing accurate measurements. This means you can take it with you anywhere, whether you're working on a construction site or outdoors in extreme weather conditions. Flexible yet professional With the Sonel MPI-530 Multimeter, you get the flexibility to measure a wide range of electrical parameters, including AC/DC voltage, current, resistance, capacitance, frequency, duty cycle, and temperature. The device is also equipped with a non-contact voltage detector that allows you to quickly and easily check for the presence of voltage in electrical circuits.So, if you're looking for a reliable and professional multimeter that can handle all your electrical needs, the Sonel MPI-530 Multifunctional Electrical Installations Meter is a perfect choice. Features MPI-530 / MPI-530-IT can be used for all measurements for the commissioning of electrical installations in accordance with applicable regulations: short circuit loop impedance (also in circuits secured with RCDs), RCD parameters, insulation resistance, earth resistance (4 measurement methods + soil resistivity measurement), continuity of protective and equipotential bondings, light intensity measurement, phase sequence test, motor rotation direction test. MPI-530 / MPI-530-IT can record 50/60 Hz power quality parameters: voltage L1 – average values in the range up to 500 V, L1 current – average values, current measurement in the range up to 3 kA (depending on the current probes used), frequency in the range of 40 Hz – 70 Hz, active (P), reactive (Q), and apparent (S) power, power factor (PF), cosφ, harmonics (up to 40th for voltage and current), total harmonic distortion (THD) for current and voltage.
Produktinformation
Produktname Multifunctional Electrical Installations Meter Sonel MPI-530
Marke Sonel
Fault loop impedance ZL-PE, ZL-N, ZL-L
Measurement range 0,13 - 1999 Ω
Display range 0 - 1999 Ω
Resolution from 0,001 Ω
Accuracy ±(%m.v. + digits) ±(5% m.v. + 0,03 Ω)
Fault loop impedance ZL-PE in RCD mode
Measurement range from 0,50 - 1999 Ω
Display range 0 - 1999 Ω
Resolution from 0,01 Ω
Accuracy ±(%m.v. + digits) ±(6% m.v. + 5 digits)
General and short-time delay RCD (TN/TT mains)
Measurement range 0 - 300 ms
Display range 0 - 300 ms
Resolution 1 ms
Accuracy ±(%m.v. + digits) ±(2% m.v. + 2 digits)
Selective RCD
Measurement range 0 - 500 ms
Display range 0 - 500 ms
Resolution 1 ms
Accuracy ±(%m.v. + digits) ±(2% m.v. + 2 digits)
For sinusoidal residual current (AC type)
Measurement range 3,3 mA - 1000 mA
Display range 3,3 mA - 1000 mA
Resolution from 0,1 mA
Accuracy ±(%m.v. + digits) ±5 % IΔn
For unidirectional residual current and unidirectional with the 6 mA DC bias (type A)
Measurement range 3,5 mA - 700 mA
Display range 3,5 mA - 700 mA
Resolution from 0,1 mA
Accuracy ±(%m.v. + digits) ±10 % IΔn
For direct residual current (type B)
Measurement range 2,0 mA - 1000 mA
Display range 2,0 mA - 1000 mA
Resolution from 0,1 mA
Accuracy ±(%m.v. + digits) ±10 % IΔn
Earth resistance - 3-pole method
Measurement range from 0,50 Ω - 1,99 kΩ
Display range 0 - 1,99 kΩ
Resolution from 0,01 Ω
Accuracy ±(%m.v. + digits) from ±(2 % m.v. + 3 digits)
Earth resistance - 4-pole method
Measurement range from 0,50 Ω - 1,99 kΩ
Display range 0 - 1,99 kΩ
Resolution from 0,01 Ω
Accuracy ±(%m.v. + digits) from ±(2 % m.v. + 3 digits)
Earth resistance - 3-pole + clamp method
Measurement range 0,00 Ω - 1,99 kΩ
Display range 0,00 Ω - 1,99 kΩ
Resolution from 0,01 Ω
Accuracy ±(%m.v. + digits) ±(8 % m.v. + 4 digits)
Earth resistance - 2-clamp method
Measurement range 0,00 Ω - 99,9 kΩ
Display range 0,00 Ω - 99,9 kΩ
Resolution from 0,01 Ω
Accuracy ±(%m.v. + digits) from ±(10 % m.v. + 4 digits)
Resistance-to-earth
Measurement range 0,00 Ωm - 99,9 kΩm
Display range 0,00 Ωm - 99,9 kΩm
Resolution from 0,1 Ωm
Accuracy ±(%m.v. + digits) Depending on accuracy
of RE measurement
Insulation resistance - Measuring voltage 50 V
Measurement range 50 kΩ - 250 MΩ
Display range 0 kΩ - 250 MΩ
Resolution from 1 kΩ
Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
Insulation resistance - Measuring voltage 100 V
Measurement range 100 kΩ - 500 MΩ
Display range 0 kΩ - 500 MΩ
Resolution from 1 kΩ
Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
Insulation resistance - Measuring voltage 250 V
Measurement range 250 kΩ - 999 MΩ
Display range 0 kΩ - 999 MΩ
Resolution from 1 kΩ
Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
Insulation resistance - Measuring voltage 500 V
Measurement range 500 kΩ - 2 GΩ
Display range 0 kΩ - 2 GΩ
Resolution from 1 kΩ
Accuracy ±(%m.v. + digits) from ±(3% m.v. + 8 digits)
Insulation resistance - Measuring voltage 1000 V
Measurement range 1000 kΩ - 9,99 GΩ
Display range 0 kΩ - 9,99 GΩ
Resolution from 1 kΩ
Accuracy ±(%m.v. + digits) from ±(3 % m.v. + 8 digits)
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA curr
Measurement range 0,12 Ω - 400 Ω
Display range 0 - 400 Ω
Resolution from 0,01 Ω
Accuracy ±(%m.v. + digits) ±(2 % m.v. + 3 digits)
Measurement of resistance with low current
Measurement range 0 Ω - 1999 Ω
Display range 0 - 1999 Ω
Resolution from 0,1 Ω
Accuracy ±(%m.v. + digits) ±(3 % m.v. + 3 digits)
Measurement in luxes (lx)
Measurement range 0 lx - 399,9 klx
Display range 0 lx - 399,9 klx
Resolution from 0,001 lx
Accuracy ±(%m.v. + digits) from ±(2% m.v. + 5 digits)
Measurement in feet-candles (fc)
Measurement range 0 fc - 39,99 kfc
Display range 0 fc - 39,99 kfc
Resolution from 0,001 fc
Accuracy ±(%m.v. + digits) from ±(2 % m.v. + 5 digits)
Specifications – 1-phase power quality recorder
Mains nominal frequency 50/60 Hz
Mains nominal voltage 110/190 V, 115/200 V,
127/220 V, 220/380 V, 230/400 V, 240/415 V
Supported systems single-phase
Alternating voltage (TRMS)
Measurement range 0 - 500 V
Max. resolution 0,1 V
Accuracy ±(%m.v. + digits) from ±(2% m.v. + 2 digits)
Alternating current (TRMS)
Measurement range depending on clamp
F-1A, F-2A, F-3A clamp 0 - 3000 A AC (10 000 Ap-p)
C-3 clamp 0 - 1000 A AC (3600 Ap-p)
C-6A clamp 0 - 10 A AC (36 Ap-p)
Max. resolution 0,1 mA
Accuracy ±(%m.v. + digits) from ±(5 % m.v. + 3 digits)
(error does not account for clamp error)
Frequency
Measurement range 45 - 65 Hz
Max. resolution 0,1 Hz
Accuracy ±(%m.v. + digits) ±(0.1 % m.v. + 1 digit)
Active, reactive, apparent and
distortion power
Measurement range 0 VA - 1,5 MVA
0 W - 1,5 MW
0 var - 1,5 Mvar
Max. resolution 1 VA
1 W
1 var
Accuracy ±(%m.v. + digits) from ±(7 % m.v. + 3 digits)
cosφ and power factor (PF)
Measurement range 0 - 1
Max. resolution 0,01
Accuracy ±(%m.v. + digits) unspecified
Harmonics - Voltage
Measurement range 0 - 500 V
Max. resolution 0,1 V
Accuracy ±(%m.v. + digits) from ±(5 % m.v. + 3 digits)
Harmonics - Current
Measurement range depending on clamp
F-1A, F-2A, F-3A clamp 0 - 3000 A AC (10 000 Ap-p)
C-3 clamp 0 - 1000 A AC (3600 Ap-p)
C-6A clamp 0 - 10 A AC (36 Ap-p)
Max. resolution as for alternating current
True RMS
Accuracy ±(%m.v. + digits) from ±(5 % m.v. + 3 digits)
(error does not account for clamp error)
THD - Voltage
Measurement range 0 - 999,9%
(in relation to the first harmonic)
Max. resolution 0,1 %
Accuracy ±(%m.v. + digits) ±5 %
THD - Current
Measurement range 0 - 999,9%
(in relation to the first harmonic)
Max. resolution 0,1 %
Accuracy ±(%m.v. + digits) ±5 %
(error does not account for clamp error)
Environmental Conditions
Ingress protection IP54
Operating temperature 0 - 50 °C
Storage temperature -20 - 70 °C
Humidity 20 - 90 %
Nominal temperature 23 ± 2 °C
Reference humidity 40 - 60 %
Measuring category acc. to EN 61010 IV 300 V, III 600 V
Type of insulation acc. to EN 61010-1 and IEC 61557 double
Data Storage
Memory 6 000 cells, 10 000 records
Computer Interface
Data transmission USB 2.0, Bluetooth
Abmessungen und Gewicht
Abmessungen (W x H x D) 223 x 288 x 75 mm (8,8 x 11,3 x 3,0 in)
Gewicht 2.5 kg (5,5 lbs)
  • WS-03 Adapter with START button with UNI-SCHUKO plug
  • AKU-07 NiMH battery 4.8 V 4.2 Ah
  • Factory calibration certificate
  • L-2 Carrying case
  • K-02 Crocodile clip, blue, 1 kV, 20 A
  • K-02 Crocodile clip, red, 1 kV, 20 A
  • K-02 Crocodile clip, yellow, 1 kV, 20 A
  • Hanging straps
  • Test lead 15 m for earth resistance measurements (on a reel, banana plugs) blue
  • Test lead 30 m for earth resistance measurements (on a reel, banana plugs) red
  • Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) blue
  • Test lead 1.2 m, 1 kV (banana plugs) red
  • Test lead 1.2 m CAT III/1000V CAT IV/600V (banana plugs) yellow
  • Cable for battery charging from car cigarette lighter socket (12 V)
  • Mains power cable 230 V (IEC C7 plug)
  • USB cable
  • Pin probe, blue 1 kV (banana socket)
  • Earth contact test probe (rod), 30 cm
  • Pin probe CAT III/1000V CAT IV/600V (banana socket) red
  • Pin probe CAT III/1000V CAT IV/600V (banana socket) yellow
  • Z-7 Power supply adapter
  • MPI-530 meter
Bluetooth wireless communication makes it simple to transmit measurement data to your computer. Use Sonel Reports PLUS software to create a report on measurements of electric shock protection. Free Sonel Reader software enables printing and saving of data in simple file formats.